AT-2035 | Mid Tier Shaker

£0.00

AT2035 Accelerometer Calibrator is perfect for simple accelerometer calibration and validation in the field or labratory setting. This portable shaker table features A2LA accredited calibration to the international standard ISO/IEC17025:2017 with a frequency range of 5 Hz – 10k Hz.

AT2035 accelerometer calibrator features two main operating modes to validate sensors or conduct system loop checks.

  •  Mode one is a “shake” operation in which the PVC operates as a simple shaker table. This is useful for performing end-to-end checks or other vibration testing where accelerometer sensitivity is not needed.

 

  • The second mode to select from is “test” mode which  sensitivity readings. These readings can be done in manual mode or full automatic mode. When performing sensitivity test in full automatic mode, a PDF certificate is also generated by the AT-2035 portable accelerometer calibrator.

Quantity:
Add To Cart

AT2035 Accelerometer Calibrator is perfect for simple accelerometer calibration and validation in the field or labratory setting. This portable shaker table features A2LA accredited calibration to the international standard ISO/IEC17025:2017 with a frequency range of 5 Hz – 10k Hz.

AT2035 accelerometer calibrator features two main operating modes to validate sensors or conduct system loop checks.

  •  Mode one is a “shake” operation in which the PVC operates as a simple shaker table. This is useful for performing end-to-end checks or other vibration testing where accelerometer sensitivity is not needed.

 

  • The second mode to select from is “test” mode which  sensitivity readings. These readings can be done in manual mode or full automatic mode. When performing sensitivity test in full automatic mode, a PDF certificate is also generated by the AT-2035 portable accelerometer calibrator.

AT2035 Accelerometer Calibrator is perfect for simple accelerometer calibration and validation in the field or labratory setting. This portable shaker table features A2LA accredited calibration to the international standard ISO/IEC17025:2017 with a frequency range of 5 Hz – 10k Hz.

AT2035 accelerometer calibrator features two main operating modes to validate sensors or conduct system loop checks.

  •  Mode one is a “shake” operation in which the PVC operates as a simple shaker table. This is useful for performing end-to-end checks or other vibration testing where accelerometer sensitivity is not needed.

 

  • The second mode to select from is “test” mode which  sensitivity readings. These readings can be done in manual mode or full automatic mode. When performing sensitivity test in full automatic mode, a PDF certificate is also generated by the AT-2035 portable accelerometer calibrator.

  • A2LA Accreditation ISO/IEC 17025:2017*

    Quartz Reference Accelerometer

    Calibrated back-to-back with a laser calibrated primary reference for increased accuracy.

    Digital closed loop control.

    Digital Electronics

    100-240v power with standard plug receptacle and built-in charger.

    Custom PC Software included to setup Full-Automatic Test Mode

    Built in Charge Converter

    Automatic PDF certificate generation tailored to your custom specifications

    Export Data to CSV.

    Option to include phase data

    Connect to a PC through Wi-Fi and control the device from a remote location with Google Chrome’s built in VNC viewer

  • The AT2035 is packed with features and functionality. Comprehensive and user-friendly software tools help operators quickly identify and address issues in their vibration system setups

    Create calibration certificates for vibration instruments.

    Test all types of vibration sensors and transducers from a variety of accelerometer and eddy current probe manufacturers.

    Provides a closed loop controlled reference signal from 5 Hz to 10,000Hz for testing over a wide frequency range.

  • The AT2035 has many applications including:

    Cabling and wiring troubleshooting

    Calibration for:

    Accelerometers

    Proximity probes and drivers

    Monitoring systems

    Charge amplifiers

    Avionics equipment

  • The built in charge amplifier can be used to read sensitivity on both differential and single-ended charge mode accelerometers. Below are some popular commonly used sensors:

    Dytran 330C1

    Dytran 3235

    Dytran 3035C

    Dytran 3055C

    Dytran 3085C

    Dytran 3088C

    Dytran 3092C

    Bently Nevada 330450

    Bently Nevada 330750

    Bently Nevada 350900

    Vibro-Meter CA 134 & CE 134

    Vibro-Meter CA 202

    Vibro-Meter CA 280

    Vibro-Meter CE 281

    Vibro-Meter CA 303

    Vibro-Meter CA 306

    Vibro-Meter CE 311

    CEC 40123

    CEC 4-125

    CEC 4-126

    CEC 4-128

    CEC 4-130

    CEC 4-137

    CEC 4-138

    CEC 4-170

    CEC 4-171

  • Universal Accelerometer Adapter Disc

    Universal Adapter Disc for Velocity Pickups

    1/4 Inch Mounting Spacer

    1/4-28 to 10-32 Stud

    1/4-28 to 1/4-28 Stud

    1/4-28 to 10-32 Adapter

    1/4-28 to 2-56 Adapter

    1/4-28 to 6-32 Adapter

    10-32 to BNC 3 foot in length low noise cable assembly

    Power Cord

    USB stick with custom PC software for auto-test and sensitivity setups.

    Short handle wrench