AT-2035 | Mid Tier Shaker
AT2035 Accelerometer Calibrator is perfect for simple accelerometer calibration and validation in the field or labratory setting. This portable shaker table features A2LA accredited calibration to the international standard ISO/IEC17025:2017 with a frequency range of 5 Hz – 10k Hz.
AT2035 accelerometer calibrator features two main operating modes to validate sensors or conduct system loop checks.
Mode one is a “shake” operation in which the PVC operates as a simple shaker table. This is useful for performing end-to-end checks or other vibration testing where accelerometer sensitivity is not needed.
The second mode to select from is “test” mode which sensitivity readings. These readings can be done in manual mode or full automatic mode. When performing sensitivity test in full automatic mode, a PDF certificate is also generated by the AT-2035 portable accelerometer calibrator.
AT2035 Accelerometer Calibrator is perfect for simple accelerometer calibration and validation in the field or labratory setting. This portable shaker table features A2LA accredited calibration to the international standard ISO/IEC17025:2017 with a frequency range of 5 Hz – 10k Hz.
AT2035 accelerometer calibrator features two main operating modes to validate sensors or conduct system loop checks.
Mode one is a “shake” operation in which the PVC operates as a simple shaker table. This is useful for performing end-to-end checks or other vibration testing where accelerometer sensitivity is not needed.
The second mode to select from is “test” mode which sensitivity readings. These readings can be done in manual mode or full automatic mode. When performing sensitivity test in full automatic mode, a PDF certificate is also generated by the AT-2035 portable accelerometer calibrator.
AT2035 Accelerometer Calibrator is perfect for simple accelerometer calibration and validation in the field or labratory setting. This portable shaker table features A2LA accredited calibration to the international standard ISO/IEC17025:2017 with a frequency range of 5 Hz – 10k Hz.
AT2035 accelerometer calibrator features two main operating modes to validate sensors or conduct system loop checks.
Mode one is a “shake” operation in which the PVC operates as a simple shaker table. This is useful for performing end-to-end checks or other vibration testing where accelerometer sensitivity is not needed.
The second mode to select from is “test” mode which sensitivity readings. These readings can be done in manual mode or full automatic mode. When performing sensitivity test in full automatic mode, a PDF certificate is also generated by the AT-2035 portable accelerometer calibrator.
-
A2LA Accreditation ISO/IEC 17025:2017*
Quartz Reference Accelerometer
Calibrated back-to-back with a laser calibrated primary reference for increased accuracy.
Digital closed loop control.
Digital Electronics
100-240v power with standard plug receptacle and built-in charger.
Custom PC Software included to setup Full-Automatic Test Mode
Built in Charge Converter
Automatic PDF certificate generation tailored to your custom specifications
Export Data to CSV.
Option to include phase data
Connect to a PC through Wi-Fi and control the device from a remote location with Google Chrome’s built in VNC viewer
-
The AT2035 is packed with features and functionality. Comprehensive and user-friendly software tools help operators quickly identify and address issues in their vibration system setups
Create calibration certificates for vibration instruments.
Test all types of vibration sensors and transducers from a variety of accelerometer and eddy current probe manufacturers.
Provides a closed loop controlled reference signal from 5 Hz to 10,000Hz for testing over a wide frequency range.
-
The AT2035 has many applications including:
Cabling and wiring troubleshooting
Calibration for:
Accelerometers
Proximity probes and drivers
Monitoring systems
Charge amplifiers
Avionics equipment
-
The built in charge amplifier can be used to read sensitivity on both differential and single-ended charge mode accelerometers. Below are some popular commonly used sensors:
Dytran 330C1
Dytran 3235
Dytran 3035C
Dytran 3055C
Dytran 3085C
Dytran 3088C
Dytran 3092C
Bently Nevada 330450
Bently Nevada 330750
Bently Nevada 350900
Vibro-Meter CA 134 & CE 134
Vibro-Meter CA 202
Vibro-Meter CA 280
Vibro-Meter CE 281
Vibro-Meter CA 303
Vibro-Meter CA 306
Vibro-Meter CE 311
CEC 40123
CEC 4-125
CEC 4-126
CEC 4-128
CEC 4-130
CEC 4-137
CEC 4-138
CEC 4-170
CEC 4-171
-
Universal Accelerometer Adapter Disc
Universal Adapter Disc for Velocity Pickups
1/4 Inch Mounting Spacer
1/4-28 to 10-32 Stud
1/4-28 to 1/4-28 Stud
1/4-28 to 10-32 Adapter
1/4-28 to 2-56 Adapter
1/4-28 to 6-32 Adapter
10-32 to BNC 3 foot in length low noise cable assembly
Power Cord
USB stick with custom PC software for auto-test and sensitivity setups.
Short handle wrench